How to adjust when the liquid level of the can filling machine is not accurate?

Views: 228 Author: Site Editor Publish Time: Origin: Site

10.10

How to adjust when the liquid level of the can filling machine is not accurate?


1. Check whether the sealing rings of all can filling machines are damaged. If damaged, please replace them with new ones.


2. Whether the speed throttle valve and the filling interval throttle valve are closed, the throttle valve cannot be closed.


3. Check whether there are foreign objects and air in the three-way control valve of the can filling machine. If so, please tidy up and try to reduce or remove the air.


4. Check whether the spool of the filling nozzle is jammed or delayed to open. If there is a jam, the spool must be reinstalled. If the opening is delayed, the throttle valve of the thin cylinder needs to be adjusted.


5. The elastic force of the coil spring in the quick-installation three-way control valve is tightened up and down. If the elastic force is too large, the check valve will not open.


6. The magnetic switch is not loose, please lock it after adjusting the amount each time.


The above is all the content introduced for you, I hope it will be helpful to you.


×

Contact Us

captcha